Saturday, October 15, 2011

Section Dimensions Don't Match the Model!!

If you ever model curved or circular structures with AutoCAD Arch. | MEP and have started your company template with the OTB Arch. or MEP template you may run into this issue.  Below I have modeled a circular concrete tank and then cut a Section right through the center of the tank.  As you can see the inner diameter of the tank is 100'-0" but when I measure the Section it measures 99'-11_1/16".  This is NO GOOD!!


After the jump see how to fix this issue...